L300P-300HFE2 57A 30KW
L300P-370HFE2 70A 37KW
L300P-450HFE2 85A 45KW
L300P-550HFE2 105A 55KW
L300P-750HFE2 135A 75KW
L300P-900HFE2 160A 90KW
L300P-1100HFE2 195A 110KW
L300P-1320HFE2 230A 132KW
L200矢量变频器
L200-002NFE 1-AC220 0.2KW L200-004NFE 1-AC220 0.4KW
L200-007NFE 1-AC220 0.75KW L200-015NFE 1-AC220 1.5KW
L200-022NFE 1-AC220 2.2KW
L200-004HFE 3-AC380 0.4KW L200-007HFE 3-AC380 0.75KW
L200-015HFE 3-AC380 1.5KW L200-022HFE 3-AC380 2.2KW
L200-040HFE 3-AC380 4.0KW L200-055HFE 3-AC380 5.5KW
L200-075HFE 3-AC380 7.5KW
L300P通用型变频器
L300P-110HFE 3-AC380 11.0KW L300P-150HFE 3-AC38015.0KW
L300P-185HFE 3-AC380 18.5KW L300P-220HFE 3-AC38022.0KW
L300P-300HFE 3-AC380 30.0KW L300P-370HFE 3-AC38037.0KW
L300P-450HFE 3-AC380 45.0KW L300P-550HFE 3-AC38055.0KW
L300P-750HFE 3-AC380 75.0KW L300P-900HFE 3-AC38090.0KW
L300P-1100HFE 3-AC380 110.0KW L300P-1320HFE 3-AC380 132.0KW
日立Sj200矢量变频器
SJ200-002NFE 1-AC220 0.2KW SJ200-004NFE 1-AC220 0.4KW
SJ200-007NFE 1-AC220 0.75KW SJ200-015NFE 1-AC220 1.5KW
SJ200-022NFE 1-AC220 2.2KW
SJ200-007HFE 3-AC220 0.75KW SJ200-004HFE 3-AC220 0.4KW
SJ200-015HFE 3-AC220 1.5KW SJ200-022HFE 3-AC220 2.2KW
SJ200-040HFE 3-AC220 4.0KW SJ200-055HFE 3-AC220 5.5KW
SJ200-075HFE 3-AC220 7.5KW
日立SJ300工程型变频器
SJ300-007HFE 3-AC380 0.75KW SJ300-015HFE 3-AC380 1.5KW
SJ300-022HFE 3-AC380 2.2KW SJ300-040HFE 3-AC380 4.0KW
故障原因:外界杂讯干扰
故障处理方法:排除杂讯干扰(如时常发生,请与我司技术部联系)
台安V2变频器故障代码:Err5
故障代表:通讯中,修改参数无效
故障原因:1、通讯中下禁止控制命令
2、通讯中修改P_192 或P_193
故障处理方法:1、通讯前必须先下致能命令
2、通讯前,先设定好参数
台安V2变频器故障代码:Err6
故障代表:通讯失败
故障原因:1.接线错误
2.通讯参数设定错误
3.和校验错误
4.通讯格式错误
故障处理方法:1.检查硬件及配线
2.检查P_192 或P_193
3.使用RS485 通讯时,JP4上跳线要插着
4.使用RS232 通讯时,JP4上跳线要拔掉
5.把CON12 的1,2脚短接把P_190 改为0
台安V2变频器故障代码:Err7
故障代表:参数设定错误
故障原因:1、企图修改P_000 或P_194~P_249
2、电压、电流侦测线路异常
故障处理方法:Reset 变频器如仍故障变频器送修
台安V2变频器故障代码:Err 8
故障代表:AV2 变位检知
故障原因:变频器报警
故障处理方法:变位检知动作